  • Brand Name: FNS
  • Place of Origin: China
  • Model Number : FNS550
  • Power : DC24V,AC85-264V(110V220V)
  • Output : 4-20mA, Pulse
  • Communication : RS-485,RS-232C
  • Mounting : Remote, Integral
  • Accuracy : 0.2%

Description

Low Cost Electromagnetic Flow Meter Converter
(1)Basic Functions
A.Sensor suitable:DN3~DN2800
B.Range of rate:0.01m/s~12m/s
C.Accuracy:Level 0.25
D.Low-frequency square wave or High-frequency Excitation
    Excitation frequency:3.125Hz,6.25Hz,12.5Hz,25Hz 
E.Excitation Current:100mA ~500mA,Default 160mA or 250mA
F.Language:Display in Chinese,English and other customized
G.Power:86V~265VAC,18V~36VDC
H.Output Signal:1.4-20mA 2.Pulse 3.Frequency 4.High and Low Alarm or Relay
I.Communication:Modbus(RS485),HART,GPRS
J.Display:Instantaneous flow rate,Velocity,Positive accumulation,Negative accumulation,Net accumulation,Signal voltage value

(2)Working Condition
Temperature:-10~60ºC
Humidity:5%~95%

Power:86V~265VAC,18V~36VDC Power Consumption<15W(With the sensor)

(3)Basic Format

A.Circular shell

B.Square shell

(4)Sensor Matching Requirements

The signal sensitivity will be 150 microV to 200 microV for 1 m/s

The excitation current can be customized from 100mA to 500mA.

The resistance for each excitation current:

    125mA is 100-120 Ohms

    160 mA is 60-100 Ohms

    250 mA is 40-60 Ohms.

(5)The Machine Accuracy

0.25%,0.5%

(6)Analog Current Output

Load resistance:0-500Ω

The basic error:0.1%±10μA

(7)Digital Frequency Output

Range:1~5000Hz

Output electrical isolation:Optoelectronic isolation.Isolation voltage:More than 1000 VDC.

Frequency output driver:Field effect tube output,Max 36 VDC power supply,Max 250 mA load current.

(8)Digital Pulse Output

The output pulse equivalent is set by client.

The output pulse width:50ms

Output electrical isolation:Optoelectronic isolation.Isolation voltage:More than 1000 VDC.

Pulse output driver:Field effect tube output,Max 36 VDC power supply,Max 250 mA load current.

(9)High and Low Alarm Output

Alarm output:H -High alarm, L -Low alarm

Output electrical isolation:Optoelectronic isolation.Isolation voltage:More than 1000 VDC.

Alarm output driver: Darlington pipe output,Max 36 VDC power supply,Max 250 mA load current.

(10)Electrical Isolation

Insulation voltage between Analog input and Analog output:not less than 500V;

Insulation voltage between Analog input and Alarm power:not less than 500V;

Insulation voltage between Analog input and AC power:not less than 500V;

Insulation voltage between Analog output and AC power:not less than 500V;

Insulation voltage between Analog output and Ground:not less than 500V;

Insulation voltage between Pulse output and AC power:not less than 500V;

Insulation voltage between Pulse output and Ground:not less than 500V;

Insulation voltage between Alarm output and AC power:not less than 500V;

Insulation voltage between Alarm output and Ground:not less than 500V.
 
Product Parameters of 4-20mA output electrode magnetic flow meter transmitter


Price

  • Price Condition : FOB
  • Price : USD110 / 1pc
  • Delivery Port : DALIAN

Packaging & Delivery

  • Packing :Carton
  • Packaging Size : 30 x 40 x 50  Centimeters
  • Package Weight : 1.5 
  • Delivery Lead Time : within 7 working days
  • Minimum Order : 1
  • Supply Ability : 1000pcs

Product Image

  • Low Cost Electromagnetic Flow Meter Converter image

Related products from premium suppliers on EC21

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Maggie Dong
Dalian Teren Instruments Co,Ltd
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Flow Meters
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.